Technical Specifications:

 

PrincipleImpedance method for RBC and PLT counting
Cyanide free reagent for hemoglobin test
Flow Cytometry (FCM) +Tri-angle laser scatter + Chemical dye
method for WBC 5-part dierential analysis and WBC counting
 Parameters
25 reportable parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%,
Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,
RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC.
12 Research parameters include LIC%, LIC#, ALY%, ALY#, PLT
Clumps#, PLT Clumps%, Lip#, Lip%, NRBC#, NRBC%, Blast#, Blast%
3 histograms for WBC, RBC and PLT
3 scattergrams for WBC dierential
Reagent

M-52D Diluent, M-52DIFF lyse, M-52LH lyse, probe cleanser

Sample VolumePrediluted mode 20 μL
Whole blood mode 15 μL
Capillary whole blood mode 15 μL
Throughput60 samples per hour
ParameterLinearity RangePrecisionCarryover
WBC0-500X109L≤ 2% (4-15 X 109L)≤ 0.5%
RBC0-8X1012L≤ 1.5% (3.5 – 6.0 X 1012L)≤ 0.5%
HGB0-250g/L≤ 1.5% (110-118g/L)≤ 0.6%
PLT0-5000X109L

≤ 6% (100-149 X 109L)

≤ 4% (150-500 X 109L)

≤ 1.0%

BC-5140, the 5-part hematology analyzer oers a great solution for clinical labs, especially for those who have limited space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling system.

Compact

Two kinds of lyse reagents are located inside of BC-5140, which helps the small labs to save space.

Utility

The 10.4 inch TFT touch screen with a wide viewing angle, brings convenience to clinicians. Users can complete all instrument operations on the screen, practically eliminating the need for an external PC.

BC-5140 inherits it’s convenient and proven powerful software design from BC-6800 and BC-3600 platforms, the friendly interface is ideal for small sized labs.

Running capillary blood through the sample probe directly is more convenient for the users in children’s hospitals, etc. For Prediluted mode, BC-5140 has higher dilution ratio than other 5-part hematology analyzers, thus it brings a better mixing eect.

4 USB ports are located on the instrument’s left side. They permit BC-5140 users to transmit data conveniently and connect with printers, keyboard, mouse, barcode scanner, etc..

BC-5140 supports bi-directional LIS with test results and patient information. HL7 protocol is supported as well.

Technology

Compared with traditional helium neon laser or argon laser, semi-conductor laser has smaller size, lower cost and longer life cycle. Improved DC impedance technology is used to count and size the RBC and PLT. The smaller counting aperture (50μm in diameter) provides better performance on samples with low PLT.

Want to Know more? Enquire Now